Wellxtrol wx 202
Wellxtrol wx 202










If that pressure gauge needle doesn't move when the water is being run or when the pump is coming on or off, it's not working properly. Sometimes these gauges lie: they get stuck or get debris clogged so they can give improper readings. Watch out: Can you trust the installed water pressure gauge?Ī separate round dial-type water pressure gauge is found on many water pump systems, at the pressure tank or near it, often on the pump itself.

#WELLXTROL WX 202 HOW TO#

If you are fine-tuning water tank bladder or air pressure be sure that you are using an accurate pressure gauge and that you know how to obtain an accurate pressure reading. How to Read Water Tank Pressure or any Pressure Gauge Accurately This is because reduction in pump cycle time can result from loss of tank air pressure which in turn can mean there may be internal corrosion and any repressurization or additional pressure could result in rupture or explosion.

  • Do not adjust the pre-charge pressure if there has been a reduction of the pump cycle time or the pre-charge pressure compared to its initial setting.
  • Do not adjust the pre-charge pressure if there is visible exterior corrosion.
  • Do not adjust or add pressure if there has been a loss of air.
  • wellxtrol wx 202

    When the Well-X-Trol has been in service and a change to a higher pre-charge pressure is necessary due to a required change in the pressure switch setting, failure to follow instructions below can cause a rupture or explosion, possibly causing serious or fatal personal injury, and/or property damage. 38 psig for models WX-205 through WX-350.īefore discussing doing anything to a bladder-type water pressure tank, read this safety warning from WELL-X-TROL, a leading well tank manufacturer:ĭANGER! EXPLOSION HAZARD Factory warnings about changing the bladder tank pressure setting.WELL-X-TROL™ water pressure tanks are shipped from the factory with a standard precharge of Some models may come with different pressure settings however. WATER TANK PRESSURE RELIEF VALVE (separate article).įactory air pressure settings in the water pressure bladder tankĪccording to Well-X-Trol bladder type well tank air precharge: typical factory set air pressure on a bladder-type residential well water tank is 18 psi. That's why your water supply system should have a Check the maximum water pressure you're using against the maximum water pressure rating for the pressure tank itself. Such an event can both flood the building and can injure anyone nearby. If the water pressure is over 70 or 80 psi your system there can be a risk of burst water piping or a burst water pressure tank. Watch out: for very high water pressure readings in your system. Please permit a safety warning before we get into the specifics of how to set the pressure in your water pressure tank. How to Select the Proper Air Pressure Charge for a Bladder-Type Well Tank We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.

    wellxtrol wx 202

    The page top photo shows the author testing the air pressure in a Well-X-Trol bladder type well tank. We detail how to fine tune the water pressure tank air charge to match the pump pressure control switch settings. We explain how to determine the proper air charge for water pressure tank and how to adjust the actual tank air pressure to that number. This article describes how to determine the proper air pressure setting in a bladder-type well tank, when, and how to actually change the air pressure in the water tank.

    wellxtrol wx 202

    How to check & then adjust or set the air pressure in a water tank using an internal bladder:

    wellxtrol wx 202

    Water pressure tank air pressure adjustment: We have no relationship with advertisers, products, or services discussed at this website. InspectAPedia tolerates no conflicts of interest.










    Wellxtrol wx 202